Table 35: TX Matrix and TX Matrix Plus Router Chassis Component Alarm
Conditions
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
------------------------Change the air filter.Change the air filter.Air filter
YellowFor technical support,
open a support case
using the Case Manager
link at
http://www.juniper.net
/support/ or call
1-888-314-JTAC (within
the United States) or
1-408-745-9500
(outside the United
States).
The router boots from
alternate boot device, the
hard disk. Typically, the router
boots from the flash drive. If
you configure your router to
boot from the hard disk, ignore
this alarm condition.
Alternative media
YellowInsert a Control Board
into an empty slot.
A Control Board was removed.Control Board
YellowReplace the failed
Control Board.
A Control Board temperature
sensor alarm has failed.
RedReplace the failed
Control Board.
A Control Board failed.
RedInsert a CIP into an
empty slot.
A CIP is missing.CIP
RedReplace the failed craft
interface.
The craft interface failed.Craft interface
YellowInstall the missing fan
tray.
One fan tray was removed
from the chassis.
Fan trays
RedInstall the missing fan
trays.
Two or more fan trays were
removed from the chassis.
RedReplace the fan tray.One fan in the chassis is not
spinning or is spinning below
the required speed.
Copyright © 2012, Juniper Networks, Inc.108
M Series and T Series Routers Monitoring and Troubleshooting Guide