user@host> show chassis environment cb
Sample Output
t640@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1805 mV
2.5 V 2501 mV
3.3 V 3293 mV
4.6 V 4725 mV
5.0 V 5032 mV
12.0 V 11975 mV
3.3 V bias 3286 mV
8.0 V bias 7589 mV
GBUS Revision 40
FPGA Revision 7
CB 1 status:
State Online Standby
Temperature 32 degrees C / 89 degrees F
Power:
1.8 V 1802 mV
2.5 V 2482 mV
3.3 V 3289 mV
4.6 V 4720 mV
5.0 V 5001 mV
12.0 V 11946 mV
3.3 V bias 3274 mV
8.0 V bias 7562 mV
GBUS Revision 40
FPGA Revision 7
Meaning The command output lists the Control Board state, redundancy status, temperature,
power supply voltages, and circuitry revision level. If you do not specify a Control Board
slot number, the command displays the environmental status for each Control Board
installed in the router chassis. If you specify a Control Board slot number, the command
displays the status for that slot only.
Check the Control Board Status from the Craft Interface
Purpose To check the Control Board status from the craft interface.
Action To check the Control Board status from the craft interface, use the following command:
user@host> show chassis craft-interface
Sample Output
t640@host> show chassis craft-interface
FPM Display contents:
[...Output truncated...}
CB LEDs:
CB 0 1
--------------
Amber . .
Green * *
389Copyright © 2012, Juniper Networks, Inc.
Chapter 14: Monitoring Control Boards