CHAPTER 21
Monitoring the CIP
•
Checklist for Monitoring the CIP on page 479
•
CIP Overview on page 480
•
Monitor the CIP Status on page 482
•
Check for CIP Alarms on page 483
•
Verify CIP Failure on page 484
•
Get CIP Hardware Information on page 486
•
Replace the CIP on page 487
Checklist for Monitoring the CIP
Purpose To monitor the Connector Interface Panel (CIP) to ensure management connection to
the M40e, M160, M320, T320, and T640 router Routing Engines, Building Integrated
Timing Source (BITS) interfaces for the Miscellaneous Control Subsystem (MCS), and
alarm relay contacts. (See Table 121 on page 479.)
Action Table 121: Checklist for Monitoring the CIP
Command or ActionTasks for Monitoring the CIP
show chassis environment“Monitor the CIP Status” on page 482
“Check for CIP Alarms” on page 483
show chassis alarms1. Display Current CIP Alarms on page 483
show log messages2. Display CIP Error Messages in the System
Log File on page 483
show log chassisd3. Display CIP Error Messages in the Chassis
Daemon Log File on page 484
“Verify CIP Failure” on page 484
Check the connector screws on the CIP faceplate.1. Check the CIP Connection on page 484
479Copyright © 2012, Juniper Networks, Inc.