Table 34: T1600 Router Chassis Component Alarm Conditions (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
YellowSet the backup SCG
online.
A backup SCG is offline.SCG
YellowReplace the failed SCG.An SCG has an out-of-range
or invalid temperature reading.
YellowInsert an SCG into an
empty slot.
An SCG was removed.
RedInsert SCGs into empty
slots or set all SCGs
online.
All SCGs are offline or missing.
RedReplace the failed SCG.An SCG failed.
YellowInsert a spare SIB into
an empty slot.
A spare SIB is missing.SIB
YellowReplace the failed SIB.A SIB failed.
YellowReplace the failed SIB.A spare SIB failed.
YellowReplace the failed SIB.A SIB has an out-of-range or
invalid temperature reading.
RedInsert a SIB into empty
slot.
A SIB is missing.
RedReplace the failed SIB.A SIB failed.
RedReset the Control
Board. If this fails,
replace the Control
Board.
A local SPMB is offline.SPMB
Copyright © 2012, Juniper Networks, Inc.106
M Series and T Series Routers Monitoring and Troubleshooting Guide