e-STUDIO556/656/756/856(Ver03) © 2012 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
6 - 30
6.4.10 Judgment threshold adjustment for blank originals
The judgment level is adjusted for automatic identification of whether the original set is blank or not.
This adjustment is made when "OMIT BLANK PAGE” is selected on the control panel.
The adjustment value is simultaneously applied to all modes at PPC and scanning.
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of P.6-25 "6.4.2 Density adjustment".
Code Item to be adjusted Contents
7618 Judgment threshold
adjustment for blank
originals
The larger the value is, the more an original tends to be judged
as a blank sheet.
Acceptable values: 0 to 255 (Default: 128)