REPLACEMENT OF PC BOARDS / HDD
9 - 30
9.2.9 License re-registration using the one-time dongle
[A] Re-registration when the board is replaced
The license registered using the one-time dongle can be re-registered only in the same equipment.
When the SYS board or SRAM board is replaced, follow the procedures for re-registration given below.
(1) Start up with the Setting Mode (08).
(2) Enter the password, and then press the [OK].
(If the password is not set for Service, press the [OK] button without entering anything.)
(3) Key in [3840], and then press the [START] button.
(4) Press the [INSTALL].
(5) Install the one-time dongle in the equipment (the one which you used for registering the selected
license), and then press the [OK].
(6) Select the license to be installed, and then press the [INSTALL].
(7) The screen for notifying that the installation will be started is displayed. Then press the [YES].
(8) After 10 to 40 seconds have passed, the screen for notifying the success of the performance is
displayed. Then press the [OK]. If the screen for notifying a failure of the performance is
displayed, quit this operation by pressing the [CLOSE]. Then check that the one-time dongle,
which you used for uploading the selected license, is installed in the equipment.
(9) Check that the installed license is displayed on the license list.
Remark:
If there are any other licenses to be returned, repeat from step (4). If there are no other licenses
to be returned, press the [CLOSE], and then turn the power OFF.
Note:
This procedure is available only with the one-time dongle used for the previous registration, since
the model information registered in it is utilized. Use the same one-time dongle and the
equipment when registering the license.
[B] Re-registration when the equipment is replaced due to malfunction
When the equipment has to be replaced due to a malfunction, return the license registered in the
equipment to the one-time dongle and register it to the new equipment following the procedure below.
(1) Start up with the Setting Mode (08).
(2) Enter the password, and then press the [OK].
(If the password is not set for Service, press the [OK] without entering anything.)
(3) Key in [3840], and then press the [START] button.
(4) Select the license to be returned, and then press the [REMOVE].
(5) Install the one-time dongle in the equipment (the one which you used for uploading the selected
license), and then press the [OK].

Table of Contents

Other manuals for Toshiba e-STUDIO556

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-STUDIO556 and is the answer not in the manual?

Toshiba e-STUDIO556 Specifications

General IconGeneral
BrandToshiba
Modele-STUDIO556
CategoryAll in One Printer
LanguageEnglish

Related product manuals