e-STUDIO556/656/756/856(Ver03) © 2012 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
11 - 50
11.6 Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
If the laser ROM version (08-9941) or the PFC ROM version (08-9940) is displayed as “NGD”, it
denotes that the updating of the ROM failed. In this case, try the firmware update again.
P.11-51 "11.7 When Firmware Updating Fails"
The installed ROM versions and the registered optional Electronic License Keys can be confirmed in
the list print mode following the procedure below.
(1) Press the [ON/OFF] button while simultaneously holding down the [9] and [STAERT] buttons.
(2) Key in “1” three times, and then press the [START] button.
(3) “VERSION LIST” is printed out.
* It is recommended to keep this list for future reinstallation such as the replacement of the SYS
board.
(4) Keep pressing the [ON/OFF] button until you hear a sound to shut down the equipment.
Firmware Code Remarks
Updating Master data
(HDD program data)
08-8952 HDD data External version
08-9900 System software version
Updating System ROM
(OS data)
08-9930 System ROM version
Updating Laser ROM 08-9941 Laser ROM version
Updating Engine ROM 08-9901 Engine ROM version
Updating Scanner ROM 08-9902 Scanner ROM version
Updating PFC ROM 08-9940 PFC ROM version
Updating RADF ROM 08-9903 RADF ROM version
Updating Finisher ROM 08-9904 Finisher ROM version
Saddle stitcher ROM version
Updating Inserter ROM 08-9942 Inserter ROM version
Updating FAX ROM 08-9905 FAX ROM version