Scanner-2
D009/D011/D012/D013/D091/D092 4-24 SM
pulley with the three windings must face the front of the machine. At the rear
of the machine, it must face the rear.
9. Perform steps 8 through 13 in "Reassembling the Front Scanner Wire".
 After replacing the scanner wire, do the image adjustments in the following
section of the manual (
p.4-101).
4.5.3 TOUCH PANEL POSITION ADJUSTMENT
 It is necessary to calibrate touch panel at the following times:
 When you replace the operation panel.
 When you replace the controller board.
 When the touch panel detection function does not operate correctly
Do not use items [2] to [9] on the Self-Diagnostic Menu. These items are for design use
only.
1. Press
, press "1", "9", "9", "3", press 5 times to open the Self-Diagnostics
menu.
2. On the touch screen press "Touch Screen Adjust" (or press "1").
3. Use a pointed (not sharp) tool to press the upper left mark
.
4. Press the lower right mark when "
" shows.