Using SP Modes
SM 5-9 D009/D011/D012/D013/D091/D092
Service
Tables
5.3.4 MEMORY CLEAR: SP5-801
Executing Memory All Clear resets all the settings stored in the NVRAM to their default
settings except the following:
Electrical total counter value
SP5-811-1: Machine serial number
SP5-907: Plug & Play Brand Name and Production Name Setting
1. Execute SP5-990 to print out all SMC Data Lists.
2. Open SP mode 5-801.
3. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to initialize
all modules or select the appropriate number from the table below.
5801-001 All Clear Initializes items 2 to 15 below.
002 Engine Clear
Initializes all registration settings for the engine
and copy process settings.
003 SCS
Initializes default system settings, SCS (System
Control Service) settings, operation display
coordinates, and ROM update information.
004 IMH Memory Clear
Initializes the image file system.
(IMH: Image Memory Handler)
005 MCS
Initializes the automatic delete time setting for
stored documents.
(MCS: Memory Control Service)
006 Copier application Initializes all copier application settings.
007 Fax application
Initializes the fax reset time, job login ID, all
TX/RX settings, local storage file numbers, and
off-hook timer.