Service Call Conditions
SM Appendix 3-23 D009/D011/D012/D013/D091/D092
Appendix:
Service Call
Conditions
SC Tables: SC6xx
610 D
Mechanical counter error: BK
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is set
to "1".
 Disconnected mechanical counter
 Defective mechanical counter
620 B
Communication error between IOB and ADF
After the ARDF is detected, the break signal occurs or communication
timeout occurs.
 Incorrect installation of ARDF
 ARDF defective
 IOB board defective
 External noise
621 D
Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
 Disconnected cable
 Defective IOB
 Defective main board in the peripherals