COPYRIGHT
©
2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JUNE 2000
CHAPTER 3 LASER EXPOSURE SYSTEM
3-11 P
5.1 Scanner Unit
1) Open the front cover.
2) Open the hopper cover [1]; then, re-
move the three screws [2], remove the
connector cover [3], and disconnect the
connector.
F03-501-01
3) Slide out the hopper unit [4].
F03-501-02
4) Remove the two screws [5], and detach
the toner dish [6].
F03-501-03
[1]
[2]
[3]
[4]
[5]
[6]
Download Free Service Manual at http://printer1.blogspot.com