CHAPTER 6 FIXING SYSTEM
6-15 P
3.2.2 Temperature Control by Mode
a.Down Sequence (text mode)
If the main thermistor (TH1) of the fixing upper roller detects any of the following levels
of temperature, the machine increases the sheet-to-sheet interval to maintain a specific fixing
temperature so as to prevent faulty fixing in continuous printing mode.
iR5000 Down Sequence
Model
Control
temperature
50 cpm return mode
40 cpm mode
35 cpm mode
print stop
100-V
170°C
165°C
160°C
155°C
120/230-V
175°C
170°C
165°C
160°C
Control
temperature
iR6000 Down Sequence
60 cpm return mode
50 cpm mode
40 cpm mode
print stop
175°C
170°C
165°C
160°C
T06-302-04
T06-302-05