COPYRIGHT
©
2000 CANON INC. 2000 2000 2000 2000 CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 7 EXTERNALS AND CONTROLS
7-9 P
3.2 Rated Outputs of the DC Power Supply
T07-302-02
* However, the AC input must be 85 to 135 V for the 100-V model, and 187 to 264 V for
the 230-V model.
T07-302-01
Output
Connector
Output voltage
tolerance
Rated output
voltage
Rated output
current
Level of activation
(overcurrent
protection)
3VA1
J4014-1
J4014-2
J4014-3
J4014-4
J4014-5
3VA2
J4017-1
J4017-2
J4017-3
J4017-4
J4017-5
±3%
3.4V
9.0A
5.5 to 8.0A
3VA3
J4003-7
3VB
J4015-1
J4015-2
J4015-3
+2%
-2.5%
3.5V
2.5A
4.0 to 8.0A
5V
J4003-5
J4004-1
J4008-1
J4009-1
J4016-1
J4016-2
±3%
5.1V
4.5A
1.0 to 5.0A
12VU
J4003-3
J4003-4
±5%
12.0V
1.0A
2.5 to 5.0A
Output
Connector
Output voltage
tolerance
Rated output
voltage
Rated output
current
Level of activation
(overcurrent
protection)
24VU1
J4005-1
24VU2
J4004-3
J4009-3
24VU3
J4003-1
J4006-1
24VU4
J4007-1
J4003-1
J4010-1
J4011-1
24VA
J4013-2
+7%
-5%
24.0V
4.0A
5.0 to 8.0A
±5%
24.0V
15.0A
5.5 to 8.0A
Download Free Service Manual at http://printer1.blogspot.com

Table of Contents

Other manuals for Canon iR5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon iR5000 and is the answer not in the manual?

Canon iR5000 Specifications

General IconGeneral
BrandCanon
ModeliR5000
CategoryAll in One Printer
LanguageEnglish

Related product manuals