CHAPTER 3 STANDARDS AND ADJUSTMENTS
3-19 T
4.14 Adjusting the Position of the Fixing Web Solenoid (SL9)
4.14.1 New Fixing Web
Adjust the position for the solenoid using the screw [2] so that the distance of travel of the
drive lever [1] is 8.6 mm.
F03-414-01
4.14.2 Existing Fixing Web
Before removing the solenoid, take note of the position [A] of the drive lever when the
solenoid turns on. After replacing the solenoid, adjust its position using the screw [2] so that
the drive lever [1] will be positioned as it was before replacement when the solenoid turns
on.
F03-414-02
8.6mm
[1]
[2]
A
[1]
[2]