CHAPTER 3 STANDARDS AND ADJUSTMENTS
3-37 T
8.5 Conversion Table for the Potential Control System
Control[V] Primary[µA] Developing bias[V] Pre-transfer[µA] Transfer[µA] Separation[µA]
3.00 1,400 0 0 440 100
3.05 1,391 3 -2 437 96
3.10 1,382 7 -4 434 92
3.15 1,373 11 -6 431 88
3.20 1,365 15 -8 429 85
3.25 1,356 18 -10 426 81
3.30 1,347 22 -12 426 77
3.35 1,338 26 -14 420 73
3.40 1,330 30 -16 418 70
3.45 1,321 33 -18 415 66
3.50 1,312 37 -20 412 62
3.55 1,303 41 -22 409 58
3.60 1,295 45 -24 407 55
3.65 1,286 48 -26 404 51
3.70 1,277 52 -28 401 47
3.75 1,268 56 -30 398 43
3.80 1,260 60 -33 396 40
3.85 1,251 63 -35 393 36
3.90 1,242 67 -37 390 32
3.95 1,233 71 -39 387 28
4.00 1,225 75 -41 385 25
4.05 1,216 78 -43 382 21
4.10 1,207 82 -45 379 17
4.15 1,198 86 -47 376 13
4.20 1,190 90 -49 374 10
4.25 1,181 93 -51 371 6
4.30 1,172 97 -53 368 2
4.35 1,163 101 -55 365 -1
4.40 1,155 105 -57 363 -5
4.45 1,146 108 -59 360 -8
4.50 1,137 112 -61 357 -12
4.55 1,128 116 -63 354 -16
4.60 1,120 120 -66 352 -20
4.65 1,111 123 -68 349 -23
4.70 1,102 127 -70 346 -27
4.75 1,093 131 -72 343 -31
4.80 1,085 135 -74 341 -35
4.85 1,076 138 -76 338 -38
4.90 1,067 142 -78 335 -42
4.95 1,058 146 -80 332 -46
Download Free Service Manual at http://printer1.blogspot.com