CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
4-33 T
4.1.34 E717
Connector
1) Is the remote diagnostic device PCB connected securely?
NO: Connect it securely.
Remote diagnostic device PCB, Main controller PCB
2) Try replacing the remote diagnostic device PCB. Is the problem
corrected?
YES: End.
NO: Replace the main controller PCB.
4.1.35 E719
Connector
1) Is the coin vendor connected securely?
NO: Connect the coin vendor securely.
Coin vendor, Main controller PCB
3) Try connecting to a different coin vendor. Is the problem corrected?
YES: End.
NO: Replace the main controller PCB.
4.1.36 E732
Wrong operation
1) Turn off and then on the main power switch. Is the problem cor-
rected?
YES: Check the operation once again; if normal, end the work.
Connectors, Reader controller PCB
2) Is the connection of the connector (J1014) on the main controller
PCB and the connector (J5004) on the reader controller PCB nor-
mal? Further, is the cable between these connectors normal?
NO: Correct the connectors/cable.
YES: Replace the reader controller PCB.
4.1.37 E733
Wrong operation
1) Turn off and then on the main power switch. Is the problem cor-
rected?
YES: Check the operation once again; if normal, end the work.