25 MODE
1 ADJUSTMENT
[8] Copy Count by Parts to be Replaced
(Fixed Parts)
This function allows you to display or reset the copy
count for a fixed part or data.
Copy count parts counter
Step Operation
1 Enter the 25 mode.
2 [Memory setting mode menu Screen]
Select “ Parts counter.”
3 [Copy count of parts menu Screen]
Select “ Count of special parts.”
4 [Copy count of special menu Screen]
Data numbers (No.), part names
(Name), and count values are displayed
in a list format.
Using and keys, select a part name.
To scroll the screen, use and keys.
5
Press the key to reset
the count value of the part highlighted.
6
Press the key to return to the
Memory setting mode menu Screen.
5
1
COUNT RESET
RETURN
NO
KRDS
para-
meter
Part name Part No.
Maximum
count
Counting condition
1 00 Web unit *1 56AA-543
99999999
Count 1 per ejected paper for single sided, 2 for
double sided
2 01 Developer *1 56AA3060 25DIPSW8-6
=0: Count 1 per ejected paper for single sided, 2
for double sided
=1: For A3, 11x17, 8k, count 2 per ejected paper
for single sided, 4 for double sided
3 02 OPC drum *1 56AA-220
4 03 Cleaning blade 56AA2010
5 04 Toner reclaim roller
unit assembly
56AA-213
(7155/7165)
56QA-213
(7255/7272)
6 05 Charging blade 56AA2503
7 06 Charger cleaning
block for upper
assembly
56AA-253
8 07 Charger cleaning
block for lower
assembly
56AA-254
9 08 Drum separation claw 56AA2070
10 09 Discharging wire 56AA2609
1-38
*1. Caution: You must reset the counter when replace these parts, otherwise image failure may occur.
4
MODEL MANUAL REVISED EDITION DATE PAGE METHOD
SERVICE MANUAL Dec. 2003
7155/7165/7255/7272
1-38 REPLACEMENT
4