5.19 ERR variable
Description
Variable ERR checks whether the preceding line has been executed correctly.
Programming
Syntax: ERR
Description: The ERR variable is read-only.
Return value:
The result of the scan can be:
FALSE = previous line was executed error-free
TRUE = previous line was not executed error-free
Example
VAR4 = Thread[VAR1,"CDM",3] ; Output value from array
IF ERR == TRUE ; Query whether the value has been found in
the array
VAR5 = "Error accessing array"
; If the value has not been found in the ar-
ray, the value "Error accessing array" is as-
signed to the variables.
ELSE
VAR5 = "All OK" ; If the value has been found in the array,
the value "All OK" is assigned to the varia-
bles.
ENDIF
Variables
5.19 ERR variable
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 111

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals