4.3 Rights management
After setting up the OPC UA components, the administrator user has read access to all data
("SinuReadAll") but not write access. These rights must be explicitly set.
Table 4-2 Methods for user administration
Method Description
GetMyAccessRights The currently connected user can read his rights.
Input Arguments:
- Rights
GetUserAccessRights The administrator can read the rights of another user.
Input Arguments:
User name Rights
DeleteUserAccess
Deletes the specified access rights for a user.
Input Arguments:
User A user whose rights are to be deleted
Realm The access rights to be deleted as a
string.
If a user wants to delete several rights,
they must be separated by a semico‐
lon.
For possible realm strings, see "GiveUserAccess".
User administration
4.3 Rights management
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 12/2017, 6FC5397-1DP40-6BA1 33

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals