2.3.5 Section [DCP]
Description
The parameters in this section define the properties of the DCP protocol (Discovery and Basic
Configuration Protocol), e.g. that are used in the menu item "Accessible nodes" of STEP 7.
InternalDcpEnabled
This can be used to switch-on and switch-off the DCP in the system network (X120); for the
NCU, the value is also used for X127.
Value: 0 or 1
Default: 1
ExternalDcpEnabled
This can be used to switch-on and switch-off the DCP in the company network (X130).
Value: 0 or 1
Default: 0
2.3.6 Section [LLDP]
Description
The parameters in this section define the properties of the LLDP protocol (Link Layer Discovery
Protocol), which is used by several applications for network diagnostics.
InternalLldpEnabled
This can be used to switch-on and switch-off the LLDP in the system network (X120); for the
NCU, the value is also used for X127.
Value: 0 or 1
Default: 1
ExternalLldpEnabled
This can be used to switch-on and switch-off the LLDP in the company network (X130).
Value: 0 or 1
Default: 0
Configuring the system
2.3 Configuration file "basesys.ini"
NCU operating system
24 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals