Identifier Parameter or property System variable
*)
MultiToolPlaceDistAngle Multitool location distance angle, angle $TC_MTPPA
MultiToolPlaceType Location type $TC_MTPP2
MultiToolPlaceTypeIdent Location type as text $TC_MTPP2
MultiToolPlaceState Multitool status in the hexadecimal notation $TC_MTPP4
MultiToolPlaceStateLocked Multitool location locked $TC_MTPP4, Bit0
MultiToolPlaceStateEmpty Multitool location empty $TC_MTPP4, Bit1
MultiToolPlaceTNo Tool number of the tool in this multitool location $TC_MTPP6
MultiToolPlaceAdaptNo Adapter number $TC_MTPP7
MultiToolPlaceNo Multitool location number -
MultiToolPlaceUser_1, … Mul‐
tiToolPlaceUser_10
OEM multitool location parameters 1 to 10 $TC_MTPPC1, …
$TC_MTPPC10
MultiToolPlaceAppl_1, … Mul‐
tiToolPlaceAppl_10
Siemens application multitool location parame‐
ters 1 to 10
$TC_MTPPCS1, …
$TC_MTPPCS10
*)
Parameter corresponds to the system variable or the system variable is the basis for this
parameter.
12.2.3 Configuring list parameters
<PARAMETERCONFIGURATION> tag
In the <PARAMETERCONFIGURATION> tag, you have the following options:
1. Changing list parameters.
2. Creating new list parameters based on an existing parameter.
Changing list parameters
You can change all list parameters included in the system.
Tool parameter identifiers (Page 181)
Cutting edge parameter identifiers (Page 183)
Monitoring parameter identifiers (Page 186)
Grinding parameter identifiers (Page 187)
Magazine location parameter identifiers (Page 188)
Magazine location adapter parameter identifiers (Page 189)
Multitool parameter identifiers (Page 189)
Tool management
12.2 Configuring the user interface
SINUMERIK Operate (IM9)