5.22 Variable S_ALEVEL
Description
The current access level can be queried in the configuration with the screen property
S_ALEVEL.
Programming
Syntax: S_ALEVEL
Description: Query of the current access level
Return value: 0: System
1: Manufacturer
2: Service
3: User
4: Key switch 3
5: Key switch 2
6: Key switch 1
7: Key switch 0
Example
REG[0] = S_ALEVEL
See also
ACCESSLEVEL (Page 126)
Variables
5.22 Variable S_ALEVEL
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 115