Functionality
5
5.1 Overview
Overview
The SINUMERIK OPC UA server provides the possibility to communicate with SINUMERIK
via OPC UA. The following functionalities of the OPC UA specification are supported by the
server:
Data Access:
Read, write and subscribe to SINUMERIK variables (NC, PLC)
Alarms & Conditions: Event based provision of SINUMERIK alarms and messages from
HMI, NC and PLC
Methods:
Transfer of part programs
This chapter describes the address space of the SINUMERIK OPC UA server and gives further
information how to address some SINUMERIK specific values. Especially since a lot of
SINUMERIK values are stored in arrays or matrices.
Furthermore the SINUMERIK alarm object is explained and it is shown how to get the alarms
from the server.
At the end of this chapter it is explained how users can transfer files from or to the server using
two comfortable methods.
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 12/2017, 6FC5397-1DP40-6BA1 35

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals