Options
If no further options are specified, the archive should represent a full backup and this should
be restored in full. The status of all files is therefore the same after the "restore" as it was at
the time of the backup.
The -full option additionally forces the partition and the file system to be recreated on the
CompactFlash Card. This is, however, possible only from a service system. -full is
necessary if the partition table and/or file system is missing or damaged.
However, if you want to restore the backup files without losing any files that have been
created in the meantime, you can use the "-nodelete" option to prevent them from being
deleted. "-nodelete" is not executed together with "-full", because all data is always deleted
when the file system is recreated.
The -addon, -oem, -user, -addon+ and -oem+ options also allow only parts of an archive
to be unpacked.
The -update option is used to load software updates supplied by Siemens. The -update
option can also be useful with -restart. If user-defined system files are changed when
loading the archive to the control, a cold restart or reinitialization is necessary. In such
cases, "sc restore" outputs an appropriate message at the end of the operation. The -restart
option causes the required action to be performed automatically.
2.5.15 Save
Description
Syntax: sc save [-full|-addon|-addon+|-oem|-oem+|-user] [-force] [-
update] FILENAME
Alternative names: backup
Authorization level: user
The "save" or "backup" action creates a backup of the CompactFlash Card in FILENAME,
which specifies the archive path and also the file name. If the action is used from a service
system, the backup receives the files of the associated control – and not the service system.
Example:
sc save -user /tmp/drv01/backup.tgz
Options
The following options are used for selecting which directories of the file system are to be written
to the archive:
-full: complete backup (default): all files of the control, incl. Boot Loader
-addon: only /addon directory
-oem: only /oem directory
-user: only /user directory (user data)
Configuring the system
2.5 Description of the actions
NCU operating system
54 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals