2.4 Service Commands
2.4.1 Using service commands
Overview
The service command 'sc' is a tool used for performing a range of service tasks on a
SINUMERIK NCU. The required action is written in the command line after the 'sc', e.g.: sc
help
This action produces a list of all actions with a short description. After the action, further
parameters or options can follow.
'sc' is available in both the NCU basic system and the service system (mostly in the form of a
USB memory.) However, some actions are only useful in one of the two systems (NCU/
Service). This is noted for each action.
See also
The most important terms and abbreviations are explained in the glossary.
Privilege levels
The 'sc' command can execute its actions using more privileges than are normally granted to
the calling user. For example, starting or stopping subsystems requires root privileges, but 'sc'
allows every user who belongs to the ‘service’ group to do this.
Each action of 'sc' is assigned a “privilege level”. This is a user group to which the user must
belong in order to execute the action. As the groups are hierarchically nested, members of
“higher” groups can also use the action in question. For example, the group 'manufact' is above
'service', which means that members of the group 'manufact' can call all actions that require
the privilege level 'service'.
The privilege level that the caller requires is noted for each individual action. The possible
levels are (in ascending order):
none
operator
user
service
manufact
Example:
An action with the privilege level 'user' can also always be executed by members of the groups
'service' and 'manufact'. Actions with privilege level ‘none’ can be called by all users.
If a user does not have the required privileges, the following error message is output:
Action 'ACTION' needs at least GROUP privilege level.
Configuring the system
2.4 Service Commands
NCU operating system
38 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals