2.7.5 POWER_OFF
Description
Identifier for a message prompting the operator to switch the machine off. The message text
is permanently saved in the system.
Programming
Identifier: POWER_OFF
Syntax: <power_off />
Attributes: --
2.7.6 WAITING
Description
After a reset of the NC or the drive, there is a wait for the restart of the respective component.
Programming
Identifier: WAITING
Syntax: <WAITING WAITINGFORNC ="TRUE" />
Attributes: waitingfornc="true" There is a wait for the restart of the NC.
waitingfordrive="true" There is a wait for the restart of the drive.
2.7.7 XML identifiers for the dialog
Dialog for the parameterization
A dialog can be configured for each device so that additional parameters can be set or output
during runtime. This is displayed by pressing the "Additional parameters" softkey.
All of the script elements described in Chapter Generating user dialogs (Page 5) can be used
to generate the dialog.
Generating commissioning dialogs
2.7 Script language
Easy XML
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 193