3.12 Program selection
3.12.1 Displaying the softkey
The softkeys on the user interface for calling the program lists are activated via general
configuration machine data.
Configuring a softkey
MD51041 $MNS_ENABLE_PROGLIST_USER
0 No softkey
1 The "Prog. list" softkey is displayed
MD51043 $MNS_ENABLE_PROGLIST_MANUFACT
0 No softkey
1 The "MANUFACTURER" softkey is displayed
Precondition
To create program lists, you require the following authorization:
"Program manager" operating area: Access level 3 (password: User) or
"Start-up" operating area: Access level 1 (password: Manufacturer).
Program lists
You can create a program list by combining desired programs from the NC data, e.g.
workpieces, part programs and subprograms. These programs can then be selected by the
PLC for execution.
Program lists Directory
plc_proglist_user.ppl /user/sinumerik/hmi/plc/programlist
plc_proglist_manufacturer.ppl /oem/sinumerik/hmi/plc/programlist
Procedure
1. Select the "Start-up" operating area if you have the authorization for ac‐
cess level 1 (password: Manufacturer).
- OR -
General settings
3.12 Program selection
SINUMERIK Operate (IM9)
46 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals