InternalLldpTLVsTxEnabled
Using this parameter, additional information in the LLDP packets are enabled at X120/X127,
which are normally not included.
Value: Numerical value from 0 ... 15
Default: 0
The value is a bit field, i.e. the total value is obtained as a sum (total) of the specified numbers,
if the corresponding information is to be sent:
1: port description
2: system name
4: system description
8: capabilities
ExternalLldpTLVsTxEnabled
Using this parameter, additional information in the LLDP packets is enabled on the X130, which
are normally not included.
Value: Numerical value from 0 ... 15
Default: 0
The value corresponds to parameter InternalLldpTLVsTxEnabled.
2.3.7 Section [LinuxBase]
Description
Additional setting possibilities of the Linux system are combined in this section.
Note
Setting the time zone and the time server
The IP addresses can also be set directly from the SINUMERIK Operate user interface in the
"Commissioning" → "Date time >" softkey operating area.
Configuring the system
2.3 Configuration file "basesys.ini"
NCU operating system
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 25

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals