The "Drive System Diagnostics" window opens.
3. Select the drive object for which you want to display further details.
4. Press the "Details" softkey.
The "Drive System Diagnostics - Details " window opens.
The name of the drive object is displayed in the window header.
Press the "Faults" softkey.
The "Drive Unit Faults" window opens that shows an overview of the faults
that have been output.
Press the "Alarms" softkey.
The "Drive Unit Alarms" window opens that shows an overview of the
alarms that have been output.
You can display the pending SI messages if Safety Integrated is integra‐
ted in your controller.
18.11 Remote diagnostics
18.11.1 Adapting remote diagnostics
Depending on the operating mode, the initiative for remote diagnostics comes from the service
provider or from the controller.
If the initiative comes from the controller, the "Request remote diagnostics" softkey is set-up.
The display of the "Request remote diagnostics" softkey is defined in the "tcu.ini" file under
the [PINGSERVICE] section.
● Variable PingServiceMode
0 = disable
1 = enable
In additional variables of this section, the data for the request telegram for service should be
set.
● Variable PingServerIP
IP address of the service provider to which the request telegram should be sent, e.g.
PingServerIP = 128.45.234.19
● Variable PingTransmissionData
A text that should be sent out as data content in the request telegram,
e.g. PingTransmissionData = help at machine 35
● Variable PingTransmissionPeriod
The length in minutes that the telegram should be sent,
e.g. PingTransmissionPeriod = 5
Service and diagnostics
18.11 Remote diagnostics
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1 453