Send documentation comments to mdsfeedback-doc@cisco.com
22-250
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show npv internal info
show npv internal info
To display internal N Port Virtualization (NPV) information, use the show npv internal info command.
show npv internal info
Syntax Description
Defaults None.
Command Modes EXEC mode.
Command History
Usage Guidelines None.
Examples The following example displays the NPV internal information.
switch# show npv internal info
NPV Globals:
============
NPV mode: ENABLED
Switch-Name: 172.20.150.98
Switch Mgmt IP Address: 172.20.150.98
proxy logo Retries: 1
Internal FLOGI max timeout Retries: -1
NS Registration max timeout Retries: 5
timer group handle: 0x30038fe0
Number of Active External Interfaces: 0
External Interface Info:
========================
Interface Information:
ifindex: fc1/1, VSAN: 1, internal FLOGI fcid: 0x1e0000
FSM current state: NPIVP_EXT_IF_ST_FLOGI_FAILED
Internal FLOGI Fail Reason: Mismatch in VSAN for this upstream port
fabric pwwn: 20:05:00:05:30:00:ca:16, fabric nwwn: 20:0a:00:05:30:00:ca:17
my pwwn: 20:01:00:05:30:01:71:b8, my nwwn: 20:01:00:05:30:01:71:b9
Port Parameters:
Rx B2B Credits: 16, Multiplier: 0, Buff Size: 2112
Tx B2B Credits: 16, Multiplier: 0, Buff Size: 2112, bbscn: 0
bbscn_capable: TRUE bbscn_max: 14, port_bbscn: 0
Timer & Retry Information:
Busy Timer (1), id: 21045, active: FALSE time remaining: 0
Fail Retry Timer (7), id: 4209, active: TRUE time remaining: 1
FDISC Response Timer (2), id: 00, active: FALSE time remaining: 0
Error Clear Timer (6), id: 71, active: TRUE time remaining: 433
This command has no other arguments or keywords.
Release Modification
3.2(1) This command was introduced.