Send documentation comments to mdsfeedback-doc@cisco.com
25-9
Cisco MDS 9000 Family Command Reference
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 25 V Commands
vsan database
vsan database
To create multiple fabrics sharing the same physical infrastructure, assign ports to VSANs, turn on or
off interop mode, load balance either per originator exchange or by source-destination ID, and enter
VSAN database submode, use the vsan database command. To remove a configuration, use the no
command in VSAN database submode.
vsan database
vsan vsan-id [interface fc slot/port | fcip fcip-id | fv slot/dpp-number/fv-port | iscsi slot/port |
port-channel portchannel-number.subinterface-number} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id} | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
vsan database
no vsan vsan-id [interface {fc slot/port | fcip fcip-id | fv slot/dpp-number/fv-port | iscsi
slot/port | port-channel portchannel-number.subinterface-number} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id} | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
Note On a Cisco Fabric Switch for HP c-Class BladeSystem and on a Cisco Fabric Switch for IBM
BladeCenter, the syntax differs as follows:
interface bay port | ext port
Syntax Description vsan vsan-id Specifies the VSAN ID. The range is 1 to 4093.
interface fc slot/port (Optional) Specifies the Fibre Channel interface by slot and port number
on a Cisco MDS 9000 Family switch.
interface bay port | ext
port
(Optional) Specifies the Fibre Channel interface by port number on a
Cisco Fabric Switch for HP c-Class BladeSystem or on a Cisco Fabric
Switch for IBM BladeCenter. The range is 0 to 48.
fcip fcip-id (Optional) Specifies the FCIP interface on a Cisco MDS 9000 Family
switch.
fv slot/dpp-number/fv-port Configures the virtual F port (FV port) interface in the specified slot
along with the data path processor (DPP) number and the FV port
number.
iscsi slot/port (Optional) Configures the iSCSI interface in the specified slot/port on a
Cisco MDS 9000 Family switch.