out-of-service xbar
out-of-service xbar
To perform a graceful shutdown of the external crossbar switching module of a Cisco MDS 9513
Director, use the out-of-service xbar command in EXEC mode.
out-of-service xbar slot
no out-of-service xbar slot
Syntax Description
Defaults None.
Command Modes EXEC.
Command History
Usage Guidelines Before removing a crossbar from an MDS 9500 Series Director, you must perform a graceful shutdown
of the crossbar.
The administrator must enter the EXEC mode out-of-service xbar command for a graceful shutdown of
the external crossbar switching module in a Cisco MDS 9513 Director.
out-of-service xbar slot
The slot refers to the external crossbar switching module slot number.
Note To reactivate the external crossbar switching module, you must remove and reinsert or replace the
crossbar switching module.
Caution Taking the crossbar out-of-service may cause supervisor switchover.
For additional information about crossbar management, refer to the Cisco MDS 9000 Family CLI
Configuration Guide.
Examples The following example shows how to perform a graceful shutdown of the external crossbar switching
module of a Cisco MDS 9513 Director.
switch# out-of-service xbar 1
slot Specifies the external crossbar switching module slot number, either 1 or 2.
Release Modification