EasyManuals Logo
Home>Siemens>Control Systems>SINUMERIK 828D

Siemens SINUMERIK 828D Commissioning Manual

Siemens SINUMERIK 828D
1167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1015 background imageLoading...
Page #1015 background image
Example
CP("D:\source.mpf","E:\target.mpf")
; Copy from source.mpf to E:\tar-
get.mpf
IF FILE_ERR > 0 ; Query whether error has occurred
IF FILE_ERR == 1 ; Query specific error numbers and
output associated error text
VAR5 = "Drive/path not available"
ELSE
IF FILE_ERR == 2
VAR5 = "Path/file access error"
ELSE
IF FILE_ERR == 3
VAR5 = "incorrect file name"
ENDIF
ENDIF
ENDIF
ELSE
VAR5 = "All OK" ; If no errors have occurred in CP
(or GC), "All OK" is output
ENDIF
5.21 FOC variable
Description
With
the variable FOC, the input focus (current active input/output field) is controlled in a dialog.
The reaction of the cursor left, right, up, down as well as PGUP, PGDN are predefined.
Note
The FOC function must not be initiated as a result of a navigation event. The cursor position
may only be changed in softkey PRESS methods, CHANGE methods, etc.
The
FOC function cannot be applied to variables with input mode wr = 0 and wr = 4 or to Help
variables.
Programming
Syntax: FOC
Description: The variable can be read and written.
Variables
5.21 FOC variable
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3 85

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D
CategoryControl Systems
LanguageEnglish

Related product manuals