4.6 Managing data
Application
The "Manage data" function is used to support and simplify the commissioning and provides
functions for backing up, loading and comparing the following data:
●
Machine data
●
Setting data
●
Drive data
●
Compensation data
In contrast to a commissioning archive, only a single control object (axis, channel, servo,
infeed, etc.) is saved in ASCII format (*.tea). This file can be edited and transferred to other
control objects of the same type. The "Manage data" function is also used to transfer drive
objects for SINAMICS drives.
Managing data
The "Manage data" function offers the following options:
● Transfer data within the control
● Save data to a file
● Load data in a file
● Compare data
The following data can be saved and stored under the following absolute path on the
CompactFlash card:
● user/sinumerik/hmi/data/backup/ec for compensation data
● user/sinumerik/hmi/data/backup/md for machine data
● user/sinumerik/hmi/data/backup/sd for setting data
● user/sinumerik/hmi/data/backup/snx for SINAMICS parameters
The function is called from "Commissioning" → "Machine data" → "Manage data".
Parameterizing machine data
4.6 Managing data
CNC commissioning
88 Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3