2.2 Data classes in the PLC
Data classes in the PLC
Assigning program blocks in data classes is used to efficiently upgrade or commission a
SINUMERIK control. Here, a distinction is made between three data classes:
● Manufacturer (M) is allocated by the machine manufacturer during construction.
● Individual (I) is allocated by the machine manufacturer during the first commissioning
(values for this specific machine).
● User (U) is set by the end customer (values associated with the particular process). You
cannot assign a different data class to the main program or to subroutines.
Block Default setting Can be changed
Main program (OB1) MANUFACTURER No
Subroutine (SBR, INT, ...) MANUFACTURER No
Data block INDIVIDUAL
MANUFACTURER
USER
Yes
Example
The data classes are assigned to the block in the dialog "Properties":
1. In the menu,"View" > "Data block", select a data block.
2. In the menu "View" → select "Properties" to change the data class.
Figure 2-1 Selecting the data class
Introduction and use of data classes
2.2 Data classes in the PLC
CNC commissioning
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3 33