6.6.4 Circularity test: Saving data
The following data can be backed up with the circularity test:
● Save parameters: The parameters entered can be saved as a file.
The following path is the default path: user/sinumerik/hmi/log/optimization/cicular/
<name>.sup
● Save graphic: If the graphic has been saved correctly the message "Data was saved"
appears, otherwise an "Error in saving the file" error message is received.
The following path is the default path: user/sinumerik/hmi/log/optimization/cicular/
<name>.sud
● Print graphic: The graphic is
saved as a pixel graphic in PNG format. Type in a name. The
name can be freely selected. The following path is the default path: user/sinumerik/hmi/log/
optimization/cicular/<name>.png
Save parameters
The file format is structured as follows (with comments in brackets[ ])
H: CstPar [Identifier for circularity test parameters]
V: 5.0 [Version number of the file format]
@Measurement
P 1: 1 [Axis number first axis]
P 2: 2 [Axis number second axis]
P 3: 0 [Measuring system Axis 1 - 0: active; 1:first; 2: second]
P 4: 0 [Measuring system Axis 2 - 0: active; 1:first; 2: second]
@ parameters
P 10: 30 [Radius]
P 11: 3000 [Feed]
P 12: 3770 [Measuring time]
P 14: 1 [Multiplier]
@Representation
P 20: 10 [Resolution]
P 21: 8 [mean / prog. radius - 8 = mean R ; 9 = prog. Radius]
Save graphic
The file format is structured as follows (with comments in brackets[ ]):
H: CstPic [Identifier for circularity test graphic]
V: 5.0 [Version number of the file format]
@ parameters
P 1: 30 [Radius]
Tuning
6.6 Circularity test
CNC commissioning