Tips and tricks
B
B.1 General tips
If possible, use the OPI version for system variables ($ variables).
Reason:
Avoids complex name resolution.
Example:
Instead of "$R[10]", it is better to use "/Channel/Parameter/R[u1,10]".
Avoids cyclic (similar) setting, e.g. of the screen and variable HLP property. Compare the
value to be set with the current value first, and only set it when it is different.
Reason:
Avoid a time-consuming search of the resolution-dependent help screens.
Example:
DEF MyVar=(R3///,"X1",,"mm"/WR1//"$AA_IM[0]")
CHANGE(MyVar)
IF MyVar.VAL < 100
HLP="mypic1.png"
ELSE
HLP="mypic2.png"
ENDIF
END_CHANGE
Recommendation:
CHANGE(MyVar)
IF MyVar.VAL < 100
IF HLP <> "mypic1.png"
HLP="mypic1.png"
ENDIF
ELSE
IF HLP <> "smypic2.png"
HLP="mypic2.png"
ENDIF
ENDIF
END_CHANGE
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3 207

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D
CategoryControl Systems
LanguageEnglish

Related product manuals