Programming
Identifier: OPTION_MD
Syntax: Area 0:
<option_md name = "Address identifier of the data" />
OR:
<option_md name = "Address identifier of the data" index= "0"/>
Area 1 to 3:
<option_md name = "Address identifier of the data" index= "Area index"/>
Attributes: name Identifier for the address, e.g. $MN_USER_DA‐
TA_INT[0]
index Identifier for the area index:
0 (default setting): Device 1 to 16
1: Device 17 to 32
2: Device 33 to 48
3: Device 49 to 64
2.6.4 PLC_INTERFACE
Description
This identifier permits the PLC ↔ HMI interface to be redefined. The system expects 128
addressable words.
Default: DB9905
Programming
Identifier: PLC_INTERFACE
Syntax: <plc_interface name = "Address identifier of the data" />
Attributes: name Identifier for the address, e.g. "plc/mb170"
Example: plc/mb170
Generating commissioning dialogs
2.6 Script language
Easy XML
134 Programming Manual, 10/2015, 6FC5397-3DP40-5BA3