Specifications and Site Requirements
Electrical Specifications
MagneMover LITE User Manual 217
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
MM LITE Power Supply
100…240V AC @ 50…60 Hz, single-phase (phase-to-phase or phase-to-neutral), 8.5 A based
on configuration and operating mode. Inrush current 35 A/115V AC, 70 A/230V AC maxi-
mum. See MM LITE Power Supply on page 188 for the mechanical drawing.
The actual power being drawn depends upon operations being performed, however all power
wiring must be sized to carry the full load.
Each MM LITE Power Supply provides two 300 W DC outputs for powering the MM LITE
motors. The number of power supplies that are required for a specific MM LITE configuration
can be determined from Table 4-9 where the maximum power consumption for each compo-
nent within the MagneMover LITE transport system is identified.
NOTE: MagneMotion
®
recommends that no more than 20 motors be powered from one MM
LITE Power supply (10 per 300 W DC output).
SHOCK HAZARD
115V AC, 6.8 A or 230V AC, 3.4 A
AC power must be disconnected before servicing.
SHOCK HAZARD
The power supply is double pole/neutral fused.
AC power must be disconnected before servicing.
NOTICE The MM LITE Power Supply uses an internal NRTL/ATL
approved power source. If a user-supplied power supply is
used in its place, it must be NRTL/ATL approved.