Maintenance
Preventive Maintenance
MagneMover LITE User Manual 363
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Refill the Lubricator on Precision Rail Vehicles
If there are lubricators that are attached to the underside of the vehicles, refill the lubricators
periodically.
NOTE: The lubricators only lubricate the running surfaces of the rails, to lubricate the entire
rail see Manually Lubricate the Precision Rails on page 362.
The frequency of lubrication depends on the distance traveled.
Required Tools and Equipment
• 68 viscosity EP mineral oil (Kluber 4 UH1-68N).
• Syringe or other injector.
MAGNETIC FIELD HAZARD: Strong magnets in use.
To avoid severe injury, people with pacemakers and other
medical electronic implants must stay away from the magnet
array on the vehicles (pucks).
PINCH/CRUSH HAZARD: Strong magnets in use.
To avoid injury from strong magnetic attractive forces:
• Handle only one vehicle (puck) or magnet array at a time.
• Do not place any body parts (for example, fingers)
between a magnet array and any ferrous material or
another magnet array.
• Vehicles (pucks) and magnet arrays not being used must
be secured individually in isolated packaging.
NOTICE Strong magnets in use.
To avoid damage to watches, instruments, electronics, and
magnetic media, keep metal tools, metal objects, magnetic
media (for example, memory disks/chips, credit cards, and
tapes) and electronics away from the magnet arrays.