Glide Puck Cleaning
The glide pucks that are used on the MagneMover LITE transport system may require clean-
ing to remove any particulate buildup on the wear surfaces of the pucks.
Required Tools and Equipment
• Disposable gloves.
• Microfiber cleaning cloth.
• Deionized water.
• Isopropyl alcohol.
MAGNETIC FIELD HAZARD: Strong magnets in use.
To avoid severe injury, people with pacemakers and other
medical electronic implants must stay away from the magnet
array on the vehicles (pucks).
PINCH/CRUSH HAZARD: Strong magnets in use.
To avoid injury from strong magnetic attractive forces:
• Handle only one vehicle (puck) or magnet array at a time.
• Do not place any body parts (for example, fingers)
between a magnet array and any ferrous material or
another magnet array.
• Vehicles (pucks) and magnet arrays not being used must
be secured individually in isolated packaging.
NOTICE Strong magnets in use.
To avoid damage to watches, instruments, electronics, and
magnetic media, keep metal tools, metal objects, magnetic
media (for example, memory disks/chips, credit cards, and
tapes) and electronics away from the magnet arrays.