B064 SERIES SERVICE MODE
B064 Series/B140 Series/G126 4-24 SM
SC600: Data Communication
SC No. Symptom Possible Cause
Communication error between BCU and scanner unit 601 D
BCU does not communicate with
scanner unit within 0.8 s after
power on.
BCU does not detect a break
signal after connecting to
scanner unit.
Communication error detected 3
times.
Serial line connection unstable
External noise on the line
BCU ADF communication/timeout abnormal 610 D
After 1 data frame is sent to the
ADF, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
Serial line connection unstable
External noise on the line
BCU ADF communication/break reception abnormal 611 D
During communication a break
(Low) signal was received from the
ADF.
Serial line connection unstable
Harness disconnected or defective
BCU ADF communication/command abnormal 612 D
An command that cannot be
executed was sent from the main
machine to the ADF.
A software error, result of an abnormal
procedure.
BCU ADF communication/timeout error 620 D
After 1 data frame is sent to the
finisher MBX, an ACK signal is not
received within 100 ms, and is not
received after 3 retries.
Serial line connection unstable
External noise on the line
BCU Finisher communication/break error 621 D
During communication with the
finisher MBX, the BCU received a
break (Low) signal from the finisher.
Serial line connection unstable
External noise on the line
BCU Tray 1~3 communication/timeout error 623 D
After 1 data frame is sent to the
trays, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
Serial line connection unstable
External noise on the line
BCU Tray 1~3 communication/break reception error 624 D
During communication with the
finisher trays, the BCU received a
break (Low) signal.
Serial line connection unstable
External noise on the line
BCU LCT communication/timeout error 626 D
After 1 data frame is sent to the
LCT, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
Serial line connection unstable
External noise on the line
BCU LCT communication/break reception error 627 D
During communication with the
LCT, the BCU received a break
(Low) signal.
Serial line connection unstable
External noise on the line
CSS (RSS) communication error between line adapter and CSS center 630 D
Japan only

Table of Contents

Other manuals for Ricoh 4051

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh 4051 and is the answer not in the manual?

Ricoh 4051 Specifications

General IconGeneral
BrandRicoh
Model4051
CategoryAll in One Printer
LanguageEnglish

Related product manuals