1B-16 Emission Control Devices:
Specifications
Service Data
B947H11207001
FI sensors
Tightening Torque Specifications
B947H11207002
Reference:
For the tightening torque of fastener not specified in this section, refer to “Tightening Torque List” in Section 0C
(Page 0C-9).
Special Tools and Equipment
Recommended Service Material
B947H11208001
Special Tool
B947H11208002
Item Specification Note
HO2 sensor output voltage
0.3 V and less at idle speed
0.6 V and more at 5 000 r/min
HO2 sensor heater resistance 6.7 – 9.5 Ω at 23 °C (73 °F)
PAIR control solenoid valve
resistance
20 – 24 Ω at 20 – 30 °C (68 – 86 °F)
EVAP system purge control
solenoid valve resistance
Approx. 32 Ω at 20 °C (68 °F) E-33 only
Fastening part
Tightening torque
Note
N⋅m kgf-m lbf-ft
HO2 sensor 25 2.5 18.0 )(Page 1B-8)
PAIR reed valve cover bolt 10 1.0 7.0 )(Page 1B-9)
EVAP system purge control solenoid valve
mounting nut
6.5 0.65 4.5
)(Page 1B-13)
EVAP system purge control solenoid valve
bracket bolt
10 1.0 7.0
)(Page 1B-13)
Material SUZUKI recommended product or Specification Note
Sealant SUZUKI BOND No.1207B or
equivalent
P/No.: 99000–31140 )(Page 1B-11)
Thread lock cement THREAD LOCK CEMENT SUPER
“1322” or equivalent
P/No.: 99000–32110 )(Page 1B-9)
09900–25008
Multi circuit tester set
)(Page 1B-10) /
)(Page 1B-15)
Manuals by Motomatrix / The Solution For Lost Motorcycle Coded Keys