1J-8 Charging System:
5) Disconnect the regulator/rectifier couplers (1). 6) Remove the regulator/rectifier as shown in the
regulator/rectifier construction. Refer to “Regulator /
Rectifier Construction” (Page 1J-7).
Installation
1) Install the regulator/rectifier as shown in the
regulator/rectifier construction. Refer to “Regulator /
Rectifier Construction” (Page 1J-7).
2) Reinstall the removed parts.
Regulator / Rectifier Inspection
B947H11A06007
Inspect the regulator/rectifier in the following procedures:
1) Turn the ignition switch OFF.
2) Disconnect the regulator/rectifier couplers. Refer to “Regulator / Rectifier Removal and Installation” (Page 1J-7).
3) Measure the voltage between the terminals using the multi-circuit testers as indicated in the following table. If the
voltage is not within the specified value, replace the regulator/rectifier with a new one. Refer to “Regulator /
Rectifier Removal and Installation” (Page 1J-7).
NOTE
If the tester reads 1.4 V and below when the tester probes are not connected, replace its battery.
Special tool
: 09900–25008 (Multi circuit tester set)
Tester knob indication
Diode test ( )
Unit: V
4) Connect the regulator/rectifier couplers and bind the clamp.
5) Reinstall the removed parts.
1
I947H11A0016-02
B2
B3
B1
B/R2 B/W2
B/R1 B/W1
I823H11A0020-04
(+) probe of tester to:
B/R
1
B/R
2
B
1
B
2
B
3
B/W
1
B/W
2
(–) probe of
tester to:
B/R
1
— 0 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.6 – 0.9 0.6 – 0.9
B/R
2
0 — 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.6 – 0.9 0.6 – 0.9
B
1
* * — * * 0.3 – 0.6 0.3 – 0.6
B
2
* * * — * 0.3 – 0.6 0.3 – 0.6
B
3
* * * * — 0.3 – 0.6 0.3 – 0.6
B/W
1
*****—0
B/W
2
*****0—
*1.4 V and more (tester’s battery voltage)