CHAPTER 2 NEW FUNCTIONS
2-152
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001
9.6 Power Save Mode
A press on the Power Save key on the control panel decreases the control temperature
used in standby state, thereby decreasing the power consumption. F02-906-01 shows the se-
quence of operations in transparency mode.
F02-906-01
Main heater
(H1)
Sub heater
(H2)
Rage of saving
of 25%
Rate of saving
of 50%
198˚C
195˚C
170˚C
105˚C
STBY SLEEP STBYWMUP
Power save
mode selected
in user mode
Power save
key ON
Power save
key OFF
195˚C 198˚C
Controlled
according to
rate of saving
Controlled to 198˚C
Controlled to 198˚C
Omits WMUPR
Returns to normal temperature
control in response to a second
press on the Power Save key.