EasyManuals Logo
Home>Cisco>Switch>Catalyst 3650 Series

Cisco Catalyst 3650 Series User Manual

Cisco Catalyst 3650 Series
1108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1090 background imageLoading...
Page #1090 background image
vmps server
To configure the primary VLAN Membership Policy Server (VMPS) and up to three secondary servers, use
the vmps server command in global configuration mode. Use the no form of this command to remove a
VMPS server.
vmps server {hostname| ip address} [primary]
no vmps server {hostname| ip address} [primary]
Syntax Description
Hostname of the primary or secondary VMPS servers. If you specify a hostname,
the Domain Name System (DNS) server must be configured.
hostname
IP address of the primary or secondary VMPS servers.
ip address
(Optional) Decides whether primary or secondary VMPS servers are being
configured.
primary
Command Default
No primary or secondary VMPS servers are defined.
Command Modes
Global configuration
Command History
ModificationRelease
This command was introduced.Cisco IOS XE 3.3SE
Usage Guidelines
The first server entered is automatically selected as the primary server whether or not primary is entered. The
first server address can be overridden by using primary in a subsequent command.
If a member device in a cluster configuration does not have an IP address, the cluster does not use the VMPS
server configured for that member device. Instead, the cluster uses the VMPS server on the command device,
and the command device proxies the VMPS requests. The VMPS server treats the cluster as a single device
and uses the IP address of the command device to respond to requests.
When using the no form without specifying the IP address, all configured servers are deleted. If you delete
all servers when dynamic access ports are present, the device cannot forward packets from new sources on
these ports because it cannot query the VMPS.
Examples
This example shows how to configure the server with IP address 191.10.49.20 as the primary VMPS server.
The servers with IP addresses 191.10.49.21 and 191.10.49.22 are configured as secondary servers:
Device(config)# vmps server 191.10.49.20 primary
Device(config)# vmps server 191.10.49.21
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
1064
vmps server

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
BrandCisco
ModelCatalyst 3650 Series
CategorySwitch
LanguageEnglish

Related product manuals