Gi1/0/1 auto off none n/a n/a 0.0
Gi1/0/2 auto off log n/a 5.4 0.0
Gi1/0/3 auto off errdisable n/a 5.4 0.0
Gi1/0/4 off off none n/a n/a 0.0
Gi1/0/5 off off log n/a 5.4 0.0
Gi1/0/6 off off errdisable n/a 5.4 0.0
Gi1/0/7 auto off none n/a n/a 0.0
Gi1/0/8 auto off log n/a 5.4 0.0
Gi1/0/9 auto on none n/a n/a 5.1
Gi1/0/10 auto on log ok 5.4 4.2
Gi1/0/11 auto on log log 5.4 5.9
Gi1/0/12 auto on errdisable ok 5.4 4.2
Gi1/0/13 auto errdisable errdisable n/a 5.4 0.0
<output truncated>
In the previous example:
•
The Gi1/0/1 port is shut down, and policing is not configured.
•
The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog message.
•
The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
•
Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is disabled.
•
Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing is
enabled with a policing action to generate a syslog message.
•
Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing is
enabled with a policing action to shut down the port.
•
The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
•
The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message, but
the switch does not apply power to the powered device.
•
The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
•
The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
•
The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
•
The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
•
The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone switch.
The table that follows describes the output fields.
Device> show power inline police gigabitethernet1/0/1
Interface Admin Oper Admin Oper Cutoff Oper
State State Police Police Power Power
--------- ------ ---------- ---------- ---------- ------ -----
Gi1/0/1 auto off none n/a n/a 0.0
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
118
show power inline

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
BrandCisco
ModelCatalyst 3650 Series
CategorySwitch
LanguageEnglish

Related product manuals