Gi1/0/1 auto off none n/a n/a 0.0
Gi1/0/2 auto off log n/a 5.4 0.0
Gi1/0/3 auto off errdisable n/a 5.4 0.0
Gi1/0/4 off off none n/a n/a 0.0
Gi1/0/5 off off log n/a 5.4 0.0
Gi1/0/6 off off errdisable n/a 5.4 0.0
Gi1/0/7 auto off none n/a n/a 0.0
Gi1/0/8 auto off log n/a 5.4 0.0
Gi1/0/9 auto on none n/a n/a 5.1
Gi1/0/10 auto on log ok 5.4 4.2
Gi1/0/11 auto on log log 5.4 5.9
Gi1/0/12 auto on errdisable ok 5.4 4.2
Gi1/0/13 auto errdisable errdisable n/a 5.4 0.0
<output truncated>
In the previous example:
•
The Gi1/0/1 port is shut down, and policing is not configured.
•
The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog message.
•
The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
•
Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is disabled.
•
Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing is
enabled with a policing action to generate a syslog message.
•
Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing is
enabled with a policing action to shut down the port.
•
The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
•
The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message, but
the switch does not apply power to the powered device.
•
The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
•
The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
•
The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
•
The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
•
The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone switch.
The table that follows describes the output fields.
Device> show power inline police gigabitethernet1/0/1
Interface Admin Oper Admin Oper Cutoff Oper
State State Police Police Power Power
--------- ------ ---------- ---------- ---------- ------ -----
Gi1/0/1 auto off none n/a n/a 0.0
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
118
show power inline