1B PWR-C1-715WAC LIT150119Z1 OK Good Good 715
Device# show env power all
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A PWR-C2-250WAC LIT16372A1M OK Good Good 250
1B Not Present
This is an example of output from the show env stack command on the active switch:
Device> show env stack
SWITCH: 1
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Temperature Value: 28 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 41 Degree Celsius
Red Threshold : 56 Degree Celsius
This example shows how to display the temperature value, state, and the threshold values on a standalone
switch. The table describes the temperature states in the command output.
Device> show env temperature status
Temperature Value: 33 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 65 Degree Celsius
Red Threshold : 75 Degree Celsius
Table 7: States in the show env temperature status Command Output
DescriptionState
The switch temperature is in the normal operating
range.
Green
The temperature is in the warning range. You should
check the external temperature around the switch.
Yellow
The temperature is in the critical range. The switch
might not run properly if the temperature is in this
range.
Red
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
72
show env