monitor capture stop
To stop the capture of packet data at a traffic trace point, use the monitor capture stop command in privileged
EXEC mode.
monitor capture {capture-name} stop
Syntax Description
The name of the capture to be stopped.
capture-name
Command Default
The packet data capture is ongoing.
Command Modes
Privileged EXEC
Command History
ModificationRelease
This command was introduced.Cisco IOS XE 3.3SE
Usage Guidelines
Use the monitor capture stop command to stop the capture of packet data that you started using the monitor
capture start command. You can configure two types of capture buffers: linear and circular. When the linear
buffer is full, data capture stops automatically. When the circular buffer is full, data capture starts from the
beginning and the data is overwritten.
Examples
To stop capturing buffer contents:
Device# monitor capture mycap stop