(Optional) Specifies a relative time, as a number of
seconds, minutes or hours from the current time, at
which to start the probe, where number is in these
ranges:
•
1 to 3600 seconds
•
1 to 1440 minutes
•
1 to 24 hours
schedule in number {seconds | minutes | hours}
(Optional) Specifies the length of the probe as a
number of seconds, minutes, or hours, where
number is in these ranges:
•
1 to 3600 seconds
•
1 to 1440 minutes
•
1 to 24 hours
The duration should not exceed the
interval specified by the repeat every
option.
Note
for duration {seconds | minutes | hours}
(Optional) Specifies the interval at which to restart
the probe as a number of seconds, minutes, or hours,
where number is in these ranges:
•
1 to 90 seconds
•
1 to 90 minutes
•
1 to 24 hours
The default is that probes are not repeated, and there
is no default interval.
repeat every number {seconds | minutes | hours}
Specifies the number of probes to run in the range
1–100. There is no default.
count probes
(Optional) Specifies that the command displays the
on-demand operation ID and exits immediately,
with the operation continuing in the background.
The default is synchronous and the operation
displays the on-demand operation ID and all results
on the console when it completes.
asynchronous
Command Default
No on-demand operations are configured or executed.
Command Modes
EXEC (#)
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
242
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
ethernet sla on-demand operation type cfm-synthetic-loss-measurement probe